SHOCK FREEZER TPSU Series Temperature range -40°C to -85°C – Made in Germany
shock freezerGENERAL OVER VIEW

Thalheimer has innovated the new technology and production of Medical Deep, Ultra Low Temperature, Freezer and the fastest Shock freezer down to – 85ºC in cooperation with specialist in the field s of electronics and thermodynamics.
All units are complied with UNI EN 61010-1/A2 (CEI 66-5), CEI EN 61326-1, R egulations on safety for laboratory equipment and ISO 9001:2008 certified manufacturer.
Different models and sizes have been pre-designed and considered as standard models offered by Thalheimer.
We have three models within the range of Deep and Ultra Low Temperature Freezers: horizontal, vertical and under counter units. Thalheimer produce different sizes from the above models and those are in the range of 85L for the under counter till 800 L which is considered as the biggest standard model.
For Shock freezer, Thalheimer offers very wide range of models starting from 100 Lit till 800 Lit for different applications of laboratory and Hospital/Medical use as well as for Research and Development institutes and Pharmaceutical industries.
Thalheimer always offer custom made design with different sizes and model based on our client’s requirement and expectation.
In general the time required to cool down the inner chamber of the ULT freezer from ambient temperatures to the selected set temperature of -80°C to -85°C is mainly depending on the
type of insulation, the efficiency of the compressor system as well as the installed metal shelves within the freezer. Thalheimer’s unit CRYO Series and Shock freezers are able to cool down within 2.15 to 3.30 hours.

STRUCTURE
– External cabinet made of zinc-plated and/or enameled steel sheets, o r, upon request, SI 304 stainless steel satin finish.
– Insulation in non-CFC, non-HCFC foamed polyurethane
– Internal casing in AISI 304 (or AISI 316 upon r equest) stainless steel, with polished exter nal BA finish for maximum resistance and cleanliness; LIFETIME WARRANTY ON STEEL PARTS
– Triple-step seal in silicone rubber for greatest prevention against air loss and ice formation; gaskets with almost unlimited durability.

– Gasket heating by means of the r efrigerant pipes on the overheated-steam side; the safest solution against ice formation, more reliable and with greater energy saving (in fact, it does not use additional sources of heat like electric resistances, etc.)
– Complete reheating compensation valve to equalize inter nal and external pressure after opening and closing the door: greatly facilitates being able to open the door after it has been opened not long ago.
– Four internal stainless steel shelves, standard in vertical models
– Insulated counter doors (in vertical models) with 20-mm. poly urethane foam, to minimize cold loss when the external door is opened;
– Insulation panels (in horizontal models) with 20-mm. polyur ethane foam, to minimize cold loss when the external door is opened;
– Highly ergonomic closing handle (in vertical models) to facilitate closi ng: just one hand and minimum force applied
– Locking handle with self-raising hinges (in horizontal models ) for maximum ease when closing and maximum operator safety.
– Lock and key for all locks
Loading System: Our innovative solution gives you the possibility to quickly load the freezer with the help of a trolley. This way the whole racket system is inserted into the freezer, giving you the chance to freeze the plasma, in the fastest time, in 2.15 minutes.
– Pivoting wheels for maximum freezer maneuverability inside the laboratory
– Insulation with CFC- and HCFC-free polyurethane resin foamed on site, with an average thickness above 140 mm
– Lock with transponder/badge available (optional); the PK (Per sonal Key) device comes complete with badge reader, management electronics, stabilized power supply at 12 Vdc 3 A and microelectronic security pistons. It is integrated with the closing system.
Optional: Trolley loading system for Shock Freezer

GENERAL TECHNICAL INFORMATION:

Capacity: Different options as per the table below
Chamber Temp.: Adjusted in the range between -40°C to -85°C (tolerance ± 2,5°C )
Body: Sheet metal zinc-plated RAL 9010
Chamber: Stainless steel, material 1.4301
Insulation: 150 mm Polyurethane, 0,19Watt/m2 K acc. DIN 52612
Door: Hermetic sealed, lockable, chromed joints full door frame heating
Shelf: Different options as per the table below
Shelf doors: For better insulation there are additional inner shelf doors
Refrigerator: Half hermetic compressor, process water cooled on the shock freezer top, shock-free mounted
Evaporator: High-performance evaporator, with fans to ensure
a high and even air circulation
Microprocessor: Temperature controller, network dependent with digital LED display/
touch panel, alarm signal if chamber temperature is too high with optical
and acoustical report, acoustical signal printable

REFRIGERATION

The refrigeration system for ULT and Shock freezers is fully sealed; it uses a cascade circuit with innovative components and fluids to obtain, together, maximum cooling reliability and performance; it has 2 silent, airtight compressors (value Leq dB (A) < 55); with a high r efrigeration capacity, furnished with magneto-thermal protection and pressure gauge to monitor maximum condensation pressure (MR): full reliability and no failures in the 1st stage; immediate identification by the user with recovery ability. The condenser surface (air with thermal r eturn above 2,610 Watt, with room T +25°C) is very large (with tubeless-execution exchangers) to endure even the most severe environmental and work conditions and to reduce power consumption.
The expansion of the refrigerating fluids is obtained through capillary tubes; the expansion occurs in fixed exchangers; the evaporating surfaces are made of: copper coils (thermally) connected to the entire external peripheral surface of the internal casing for horizontal freezers, and evaporation trays in AISI 304 stainless steel – placed inside the internal chamber for vertical freezers; both solutions guarantee high refrigeration capacity, very fast cooling (reduced pull down and recovery times), and elevated uniformity of the internal temperature.
The whole thermal fluid dynamics circuit is built to provide maximum functionality (efficiency, reliability) and facilitate maintenance operations. The refrigerants being used are non-toxic, non-flammable, non-explosive and environmentally friendly (maximum respect for the environment): HC free, CFC free, HCFC free (ODP = OZONE DEPLETION POTENTIAL = 0).
The freezers at -40°C have the same construction characteristics as t hose of the -85°C, with the exception of the second compressor system in cascade.

VOLTAGE STABILIZER

4,000-VA voltage regulation, capable of compensating the fluctuations of the utili ty power supply (± 15%), protecting the compressors and guaranteeing a long useful life.

Defrosting: Automatic defrosting, should be initiated by user, pre-programmable
up to 7 days in real time
Cooling-system: After receiving the defrost end temperature the deep freeze system will
switch on automatically. The shock room will be adjusted to the preselected
temperature.

It depends on the daily usage how often you have to defrost;
hereby it’s important that the insertion of the deep freeze goods happens
fast. Resulting from our many years of experience we know that the deep
freeze system (when daily used) should be defr osted within 158 hrs., one
defrosting cycle will take up to 36 hrs.
Defrost water: Will be led away from shock freezer via a condensate pump into the
technical room and into a sewage disposal.

 

TECHNICAL DATA

Voltage: 400V – 50Hz – 3ph
Acoustic pressure: 71 dB (A)
Cooling liquid: 1st stage R 404a CFC free
2nd stage R 23 FCF free
Process water: temperature VL. +8°/+12° RL. +19°
Water flow: at full performance approx. 900ltr./hr.
Pressure loss: 0.20 bar

 

MODEL NAME CAPACITY DIMENSIONS MM
  Net volume/ number of chambers Outside (WxDxH) Interior (WxDxH)
       
TPSU / 800LSF 800L / 4C 1720 x 800 x 2400 920x590x1500
TPSU / 700LSF 700L / 4C 1600x880x2400 800x590x1500
TPSU / 600LSF 600L / 4C 1600x880x2200 800x590x1300
TPSU / 500LSF 500L / 3C 1600x880x1990 800x590x1140
TPSU / 400LSF 400L / 2C 1450x880x1990 650x590x1140
TPSU / 280LBF 280L / 2C 1200x880x2200 800 x 590 x 300
TPSU / 185LUF 185L/1C 1200x880x1930 800 x 590 x 400
TPSU/100LUF 100L /1C 940x840x1930 540 x 540 x 400

CONTROL SYSTEM

All our controllers (with touch panel), are developed, programed and produced in-house. Thalheimer Soft Engineering division which is a member of Thalheimer group of companies is specialized in electronic and program research, development and production of all PLCs and controllers.
All controllers are designed with a technology based on microprocessor ARM9, Dual Core, similar to those applied in smart-phones.
The system is designed to control, record, supervise with full traceability of all requested parameters and events. It features full connectivity to the environmental and very safe during the operational process with an easy access.
The system consist of 2 monitoring kit with two independent R TD Pt 100 Ω (class A) sensors; one for the regulation and one for the temperature alarm and for automatic recording of the temperature and the alarms; The recording is being done in real time for all functions which are being automatically recorded on the SD card and USB port.
The SD Card and USP port are located in the front panel near to the touch screen, and the user can easily download the required data of thermal recording as well as updating the software whenever needed.
The controller works with operative system Linux and it’s a true on – board computer. It has a graphic interface with touch screen TFT display The microprocessor has significant high capacity of memory RAM, with a frie ndly used interface having full access on reading and managing the operation by means of USB, SIM, Wi-Fi, Ethernet wired, and RS485 port with ModBus protocol.
Above all, the Wi-Fi connection makes the unit visible thr ough the LAN line of the hospital or of the industrial laboratory.
Using any PC work station that is connected in the same network where the freezer unit is linked, you can easily browse and get connected to the freezer control system. This can be accessed by typing the IP address of the unit which is a unique IP for each freezer. Moreover you can access the controller through the internet by accessing the static IP address of the institute network in which the controller of the freezer is connected any recording requirement are being designed and managed through our updated controller with which you can have the possibilities to scan bar codes for inventory purposes as well as detect and record the identification of the operator using the unit at each acti on. All data can be transferred from the controller to any PC using windows software.
The data recording system and software of our controller has been developed to be complied with most evolved standards as, GMP, JACIE, FACT etc.

ACCESS CONTROL / MAINTENANCE

The controller of our units has an access code. It is designed with the possibility to use an electronic key (alphanumerical code customized by the user) to put togethe r with an electrical lock for a controlled door opening, or as optional equipment, to use a badge or transponder (or finger pass, with the finger print storage).
The easily designed software management of the controller makes it very simple and friendly to the user with self-explanatory process and guidance.
All data in the controller can be safely accessed remotely through the IP address which enables the user to download all data related to the status of the unit, the authorized maintenance technician can also change or modify the parameters remotely.

ALARMS

The alarm system is managed totally with an independent microprocessor and electronic board.
Usually the user get visual and acoustic alarm during the following faults:
– Power failure
– Door opening for a long time, total opening time ar e all recorded in the memory
– High condenser pressure
– Low Battery
– Damaged probe
– Long working time of the compressors
– High condenser’s temperature
– Blocked / dirty condenser ventilation
– Low temperature / High temperature in the inner chamber
– In case of Shock freezer / alarm for product reching temperature

ENVIRONMENTAL ADAPTABILITY

The condenser ventilation system is being managed separately by means of a sensor; having such advance feature, it allows the condenser fan to change the mode of operation speed based on the ambient condition.

GSM MODULE

This is an optional feature which enables the alarm system to send trouble shooting SMS to a pre-defined mobile phone number. It is also possible to have dif ferent phone number for different levels of trouble shooting and messages.

 

BAR CODE READER

This is an optional feature which can be incorporated in the control system to scan a bar code of the product for inventory use.

 

ENERGY SAVING CONTROL

ECO MODE allows raising the temperature set during night.
ENERGEY SAVING MODE raise, automatically and for a temporarily period, the temp set point once the compressors usage has reached its pre-defined limit. This automatic activation of energy saving operation maintains the energy consumption and usage of the compressors to the minimum and in a most economical way. The set point will be re-set back automatically after a defined period of time so as the unit will work in a normal energy mode.
It has been calculated that we can save an energy consumption of 15% compared to the normal freezers working without the above features.
All our controllers are made to accept future updating in software as well as modification of its features to match and get complied to all standard and requirement in health sector.